Brief introduction of differential to Pulse signal transmitter of Servo Encoder
Application design
DC/DC module power supply has a variety of standard input voltage, output voltage and output power and any special combination. Some module power supplies provide a variety of power levels with the same physical package and the same pins. If the index change requires more power, such as an increase in output from 100 to 150W, a higher power module power supply can be used to keep design changes to a minimum.
Extremely light application
In general, the module power supply has a minimum load limit, which varies from manufacturer to manufacturer, generally about 10%, because when the load is too light, it is difficult for the energy storage component to continue flow, and the current is discontinuous, resulting in unstable output voltage. this is determined by the working principle of the module power supply itself. If there is indeed light or no-load use, the most convenient and effective way is to add a certain false load, which is about 2% of the output power, which can be preset by the module power manufacturer before leaving the factory. It can also be used by the user to set an appropriate resistance outside the module power supply as the load. It is worth noting that if the former is chosen, the power efficiency of the module will be reduced. However, some circuit topologies have no minimum load limit, such as Ericsson's E-series module power supply, which can meet the normal use of load from no-load to full load.
Main features:
The encoder differential signal is directly input and converted into pulse signal.
Simultaneous conversion of A, B and Z is supported.
3 inputs, 3 outputs, optional output pulse amplitude
The response speed is above 500KHz without changing the frequency of the original waveform.
3000VDC isolation of power supply, signal input and signal output
Power supply: 5V, 12V, 15V or 24V DC single power supply
Low cost, small size, easy to use and high reliability
Standard DIN35 rail installation
Size: 120 mm x 70 mm x 43mm
Industrial grade temperature range:-45 ~ + 85 ℃
Application:
Encoder differential signal isolation, acquisition and conversion
Conversion of encoder differential signal to 24V square wave pulse
Differential signal of servo encoder is transmitted to PLC
Pulse signal amplification
Ground interference suppression
Motor speed monitoring system
Speed measurement and alarm
Signal distortionless transmission and transmission
Product selection table:
Characteristic code Power code characteristic code
24VDC P1 output level 0-5V O1
Single-ended signal input
Amplitude peak to peak (VP-P): 5V S2 12VDC P2 output level 0-12V O2
Single-ended signal input
Amplitude peak to peak (VP-P): 12V S3 5VDC P3 output level 0-24V O3
Single-ended signal input
Amplitude peak to peak (VP-P): 24V S4 15VDC P4 collector open circuit output O4
5V differential pulse signal input S5
User customized Su user customized Ou
Examples of type selection:
Example 1: input: encoder differential signal input; power supply: 24V; output: 0-5V level model: DIN33 IBF S5-P1-O1
Example 2: input: encoder differential signal input; Power supply: 12V; output: 0-24V level Model: DIN33 IBF S1-P2-O3
Example 3: input: 0-5V level; Power supply: 24V; output: 0-24V level Model: DIN33 IBF S2-P1-O3
Example 4: input: 0-5V level; power supply: 12V; output: collector open circuit output model: DIN33 IBF S2-P2-O4
Example 5: input: user-defined; Power supply: 24V; output: user-defined model: DIN33 IBF Su-P1-Ou
General parameter
Isolated voltage 1min 1500 3000 VDC
Signal input amplitude (VP-P) 0.210 60V
Frequency 0 10 500 kHz
Input impedance 10 k Ω
Input current 5V input 0.45 mA
Signal output amplitude (VP-P) O1: output level 0-5V 5V
Frequency 0 10 500 kHz
Voltage (high level) O1: output level 0-5V 5V
Voltage (low level) 0 0.05 V
Current (high level) 2 5 mA
Current (low level) 2 8 mA
Voltage O4: collector open circuit output 530V
Current 3 10 mA
Response time 1500 ns
Auxiliary power supply voltage user customized 3.312 24 VDC
Current VD=12V 150mA
Auxiliary power consumption 2 W
Working ambient temperature-45 85 ℃
Storage temperature-45 85 ℃
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.