Brief introduction of Servo Encoder differential 24v to 0-12v Pulse signal transmitter

2025-02-21 Update From: SLTechnology News&Howtos shulou NAV: SLTechnology News&Howtos > Internet Technology >

Share

Shulou(Shulou.com)06/03 Report--

Brief introduction of differential to Pulse signal transmitter of Servo Encoder

Application design

DC/DC module power supply has a variety of standard input voltage, output voltage and output power and any special combination. Some module power supplies provide a variety of power levels with the same physical package and the same pins. If the index change requires more power, such as an increase in output from 100 to 150W, a higher power module power supply can be used to keep design changes to a minimum.

Extremely light application

In general, the module power supply has a minimum load limit, which varies from manufacturer to manufacturer, generally about 10%, because when the load is too light, it is difficult for the energy storage component to continue flow, and the current is discontinuous, resulting in unstable output voltage. this is determined by the working principle of the module power supply itself. If there is indeed light or no-load use, the most convenient and effective way is to add a certain false load, which is about 2% of the output power, which can be preset by the module power manufacturer before leaving the factory. It can also be used by the user to set an appropriate resistance outside the module power supply as the load. It is worth noting that if the former is chosen, the power efficiency of the module will be reduced. However, some circuit topologies have no minimum load limit, such as Ericsson's E-series module power supply, which can meet the normal use of load from no-load to full load.

Main features:

The encoder differential signal is directly input and converted into pulse signal.

Simultaneous conversion of A, B and Z is supported.

3 inputs, 3 outputs, optional output pulse amplitude

The response speed is above 500KHz without changing the frequency of the original waveform.

3000VDC isolation of power supply, signal input and signal output

Power supply: 5V, 12V, 15V or 24V DC single power supply

Low cost, small size, easy to use and high reliability

Standard DIN35 rail installation

Size: 120 mm x 70 mm x 43mm

Industrial grade temperature range:-45 ~ + 85 ℃

Application:

Encoder differential signal isolation, acquisition and conversion

Conversion of encoder differential signal to 24V square wave pulse

Differential signal of servo encoder is transmitted to PLC

Pulse signal amplification

Ground interference suppression

Motor speed monitoring system

Speed measurement and alarm

Signal distortionless transmission and transmission

Product selection table:

Characteristic code Power code characteristic code

24VDC P1 output level 0-5V O1

Single-ended signal input

Amplitude peak to peak (VP-P): 5V S2 12VDC P2 output level 0-12V O2

Single-ended signal input

Amplitude peak to peak (VP-P): 12V S3 5VDC P3 output level 0-24V O3

Single-ended signal input

Amplitude peak to peak (VP-P): 24V S4 15VDC P4 collector open circuit output O4

5V differential pulse signal input S5

User customized Su user customized Ou

Examples of type selection:

Example 1: input: encoder differential signal input; power supply: 24V; output: 0-5V level model: DIN33 IBF S5-P1-O1

Example 2: input: encoder differential signal input; Power supply: 12V; output: 0-24V level Model: DIN33 IBF S1-P2-O3

Example 3: input: 0-5V level; Power supply: 24V; output: 0-24V level Model: DIN33 IBF S2-P1-O3

Example 4: input: 0-5V level; power supply: 12V; output: collector open circuit output model: DIN33 IBF S2-P2-O4

Example 5: input: user-defined; Power supply: 24V; output: user-defined model: DIN33 IBF Su-P1-Ou

General parameter

Isolated voltage 1min 1500 3000 VDC

Signal input amplitude (VP-P) 0.210 60V

Frequency 0 10 500 kHz

Input impedance 10 k Ω

Input current 5V input 0.45 mA

Signal output amplitude (VP-P) O1: output level 0-5V 5V

Frequency 0 10 500 kHz

Voltage (high level) O1: output level 0-5V 5V

Voltage (low level) 0 0.05 V

Current (high level) 2 5 mA

Current (low level) 2 8 mA

Voltage O4: collector open circuit output 530V

Current 3 10 mA

Response time 1500 ns

Auxiliary power supply voltage user customized 3.312 24 VDC

Current VD=12V 150mA

Auxiliary power consumption 2 W

Working ambient temperature-45 85 ℃

Storage temperature-45 85 ℃

Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.