In addition to Weibo, there is also WeChat
Please pay attention
WeChat public account
Shulou
2025-02-22 Update From: SLTechnology News&Howtos shulou NAV: SLTechnology News&Howtos > Network Security >
Share
Shulou(Shulou.com)06/01 Report--
1. CRC error packet statistics appear under the port
For example:
XGigabitEthernet0/0/1 current state: UP
Line protocol current state: UP
Description:
Switch Port, Link-type: access (negotiated)
PVID: 1, TPID: 8100 (Hex), The Maximum Frame Length is 9012
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 4cf9-5d39-efa0
Current system time: 2017-12-08 14:10:22
Port Mode: COMMON FIBER, Transceiver: UNKNOWN_SFP
Speed: 10000, Loopback: NONE
Duplex: FULL, Negotiation: DISABLE
Mdi: -, Flow-control: DISABLE
Last 300 seconds input rate 1981032 bits/sec, 789 packets/sec
Last 300 seconds output rate 13763216 bits/sec, 1234 packets/sec
Input peak rate 3900736744 bits/sec, Record time: 2016-12-20 15:58:51
Output peak rate 1579418400 bits/sec, Record time: 2017-06-11 07:56:25
Input: 8074383226 packets, 3301841306523 bytes
Unicast: 8072437737, Multicast: 1008305
Broadcast: 1, Jumbo: 0
Discard: 0, Pause: 937183
Frames: 0
Total Error: 828399
CRC: 838399, Giants: 0
Runts: 0, DropEvents: 0
Alignments: 0, Symbols: 0
Ignoreds: 0
Output: 11492763448 packets, 15396671657189 bytes
Unicast: 11475385794, Multicast: 16770945
Broadcast: 606709, Jumbo: 0
Discard: 12, Pause: 0
Total Error: 0
Collisions: 0, Late Collisions: 0
Deferreds: 0
Input bandwidth utilization threshold: 80.005%
Output bandwidth utilization threshold: 80.005%
Input bandwidth utilization: 0.02%
Output bandwidth utilization: 0.14%
If it is found that there is an error packet of CRC in the Input direction of the interface, it means that there has been or exists the phenomenon of error packet in the upstream packet.
Need to troubleshoot
Solution: check the status of upstream equipment, whether there is packet loss, abnormal optical power and so on.
If it has occurred before, but the data has not been cleared, you need to observe whether the number of packets has increased. If not, you can clear the statistics under the API to avoid unnecessary errors. Clear all the data statistics under the interface by using the command reset count interface XG 0Unitable1.
two。 Check the parameter information of the optical module, there is an exception
[G14_WR_NE20E_A-diagnose] display optical-module extend information slot 17 card 14
=
Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated
= | =
Card14-Port0 + Value HighAlarm HighWarn LowWarn LowAlarm Status
-|-
Temperature (C) 34.527 80.000 70.000 0.000-10.000 Normal
Supply Voltage (V) 3.307 3.630 3.465 3.135 2.970 Normal
Tx Bias (mA) 5.340 20.000 15.000 1.000 1.000 Normal
Tx Power (avg dBm)-2.281 0.999-1.000-7.300-9.299 Normal
Rx Power (avg dBm)-40.000 0.999-1.000-9.901-11.897 Abnormal
= | =
Display transceiver interface gigabitethernet 0/0/1 verbose
The accepted optical power is too low, maybe the optical fiber is not connected properly, or the opposite end does not emit light.
3. The power supply display is not normal
Display power
Slot PowerID Online Mode State Power (W)
1 PWR1 Present AC NotSupply 150.00
1 PWR2 Present AC Supply 150.00
2 PWR1 Present AC NotSupply 150.00
2 PWR2 Present AC Supply 150.00
AC is AC power supply.
DC is DC power supply
Possible reasons:
The customer is a single power supply and there is no second power supply module.
There is a second power supply, but there is no power on.
It is true that the power supply is down.
4. The running configuration file is inconsistent with the saved configuration file
Display configuration changes
5.SNMP protocol version check
Display snmp-agent sys-info version
SNMP version running in the system:
SNMPv2c SNMPv3
When configuration occurs, multiple versions of SNMP are compatible at the same time and have no effect.
6. Judge whether the operation will affect the business according to the rate reported in the current network.
Display interface GigabitEthernet2/0/12
Last 300 seconds input rate 448792 bits/sec, 62 packets/sec
Last 300 seconds output rate 506664 bits/sec, 71 packets/sec
Add up the packet rates of input and output several times to determine whether there are a large number of services running
7. MAC address drift occurs
Display trapbuffer
# Feb 8 2017 18 Feb 37 18 Feb 08 MAC move detected 00 C05_NAS_S5720_CSS L2IFPPI/4/MFLPVLANALARM:OID 1.3.6.1.4.1.2011.5.25.160.3.7 MAC move detected, VLANID = 3, MacAddress = 244c-0733-3205, Original-Port = Eth-Trunk100, Flapping port = XGE1/0/1. Please check the network accessed to flapping port.
Possible reasons:
Client's movement-A simple MAC drift appears in the log at this time, with no effect
However, if there are a large number of MAC drift logs, showing the same mac drift, there may be a two-layer loop, or suffer from *, check the status of stp, MAC drift table
Display mac-address flapping record
Move-Time VLAN MAC-Address Original-Port Move-Ports MoveNum
SJV 2011-08-31 17:22:36 300 0000-0000-0007 Eth-Trunk1 Eth-Trunk2 81
2011-08-31 17:22:44
You can configure the maximum number of MAC that can be accessed by configuring the same priority of MAC address that cannot be overridden and statically bound.
8. The veneer is not working properly.
Display device
CE12808's Device status:
Slot Card Type Online Power Register Alarm Primary
1-CE-L48XS-EC Present On Registered Normal NA
3-CE-L48GS-EA Present On Registered Normal NA
5-CE-L48GT-EA Present On Registered Normal NA
9-CE-MPUA Present On Registered Normal Master
10-CE-MPUA Present On Registered Normal Slave
11-CE-CMUA Present On Registered Normal Master
12-CE-CMUA Present On Registered Normal Slave
13-CE-SFU08A Present On Registered Normal NA
14-CE-SFU08A Present On Registered Normal NA
15-CE-SFU08A Present On Registered Normal NA
16-CE-SFU08A Present On Registered Normal NA
17-CE-SFU08A Present On Registered Normal NA
18-Present Off Unregistered-NA
PWR1-PAC-2700WA Present On Registered Normal NA
PWR2-PAC-2700WA Present On Registered Normal NA
PWR3-PAC-2700WA Present On Registered Normal NA
PWR4-PAC-2700WA Present On Registered Normal NA
PWR5-PAC-2700WA Present On Registered Normal NA
PWR6-PAC-2700WA Present On Registered Normal NA
PWR7-PAC-2700WA Present On Registered Normal NA
PWR8-PAC-2700WA Present On Registered Normal NA
FAN1-FAN-12C Present On Registered Normal NA
FAN2-FAN-12C Present On Registered Normal NA
FAN3-FAN-12C Present On Registered Normal NA
FAN4-FAN-12C Present On Registered Normal NA
FAN5-FAN-12C Present On Registered Normal NA
FAN6-FAN-12C Present On Registered Normal NA
FAN7-FAN-12C Present On Registered Normal NA
FAN8-FAN-12C Present On Registered Normal NA
FAN9-FAN-12C Present On Registered Normal NA
FAN10-FAN-12C Present On Registered Normal NA
FAN11-FAN-12C Present On Registered Normal NA
FAN12-FAN-12C Present On Registered Normal NA
FAN13-FAN-12C Present On Registered Normal NA
Display switchover state
Switchover State: Ready
Switchover Policy: Board Switchover
MainBoard: 9
SlaveBoard: 10
It is recommended to check whether the veneer is plugged in or replaced. There may be no plug-in card.
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.