1. CRC error packet statistics appear under the port

For example:

XGigabitEthernet0/0/1 current state: UP

Line protocol current state: UP

Description:

Switch Port, Link-type: access (negotiated)

PVID: 1, TPID: 8100 (Hex), The Maximum Frame Length is 9012

IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 4cf9-5d39-efa0

Current system time: 2017-12-08 14:10:22

Port Mode: COMMON FIBER, Transceiver: UNKNOWN_SFP

Speed: 10000, Loopback: NONE

Duplex: FULL, Negotiation: DISABLE

Mdi: -, Flow-control: DISABLE

Last 300 seconds input rate 1981032 bits/sec, 789 packets/sec

Last 300 seconds output rate 13763216 bits/sec, 1234 packets/sec

Input peak rate 3900736744 bits/sec, Record time: 2016-12-20 15:58:51

Output peak rate 1579418400 bits/sec, Record time: 2017-06-11 07:56:25

Input: 8074383226 packets, 3301841306523 bytes

Unicast: 8072437737, Multicast: 1008305

Broadcast: 1, Jumbo: 0

Discard: 0, Pause: 937183

Frames: 0

Total Error: 828399

CRC: 838399, Giants: 0

Runts: 0, DropEvents: 0

Alignments: 0, Symbols: 0

Ignoreds: 0

Output: 11492763448 packets, 15396671657189 bytes

Unicast: 11475385794, Multicast: 16770945

Broadcast: 606709, Jumbo: 0

Discard: 12, Pause: 0

Total Error: 0

Collisions: 0, Late Collisions: 0

Deferreds: 0

Input bandwidth utilization threshold: 80.005%

Output bandwidth utilization threshold: 80.005%

Input bandwidth utilization: 0.02%

Output bandwidth utilization: 0.14%

If it is found that there is an error packet of CRC in the Input direction of the interface, it means that there has been or exists the phenomenon of error packet in the upstream packet.

Need to troubleshoot

Solution: check the status of upstream equipment, whether there is packet loss, abnormal optical power and so on.

If it has occurred before, but the data has not been cleared, you need to observe whether the number of packets has increased. If not, you can clear the statistics under the API to avoid unnecessary errors. Clear all the data statistics under the interface by using the command reset count interface XG 0Unitable1.

two。 Check the parameter information of the optical module, there is an exception

[G14_WR_NE20E_A-diagnose] display optical-module extend information slot 17 card 14

=

Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated

= | =

Card14-Port0 + Value HighAlarm HighWarn LowWarn LowAlarm Status

-|-

Temperature (C) 34.527 80.000 70.000 0.000-10.000 Normal

Supply Voltage (V) 3.307 3.630 3.465 3.135 2.970 Normal

Tx Bias (mA) 5.340 20.000 15.000 1.000 1.000 Normal

Tx Power (avg dBm)-2.281 0.999-1.000-7.300-9.299 Normal

Rx Power (avg dBm)-40.000 0.999-1.000-9.901-11.897 Abnormal

= | =

Display transceiver interface gigabitethernet 0/0/1 verbose

The accepted optical power is too low, maybe the optical fiber is not connected properly, or the opposite end does not emit light.

3. The power supply display is not normal

Display power

Slot PowerID Online Mode State Power (W)

1 PWR1 Present AC NotSupply 150.00

1 PWR2 Present AC Supply 150.00

2 PWR1 Present AC NotSupply 150.00

2 PWR2 Present AC Supply 150.00

AC is AC power supply.

DC is DC power supply

Possible reasons:

The customer is a single power supply and there is no second power supply module.

There is a second power supply, but there is no power on.

It is true that the power supply is down.

4. The running configuration file is inconsistent with the saved configuration file

Display configuration changes

5.SNMP protocol version check

Display snmp-agent sys-info version

SNMP version running in the system:

SNMPv2c SNMPv3

When configuration occurs, multiple versions of SNMP are compatible at the same time and have no effect.

6. Judge whether the operation will affect the business according to the rate reported in the current network.

Display interface GigabitEthernet2/0/12

Last 300 seconds input rate 448792 bits/sec, 62 packets/sec

Last 300 seconds output rate 506664 bits/sec, 71 packets/sec

Add up the packet rates of input and output several times to determine whether there are a large number of services running

7. MAC address drift occurs

Display trapbuffer

# Feb 8 2017 18 Feb 37 18 Feb 08 MAC move detected 00 C05_NAS_S5720_CSS L2IFPPI/4/MFLPVLANALARM:OID 1.3.6.1.4.1.2011.5.25.160.3.7 MAC move detected, VLANID = 3, MacAddress = 244c-0733-3205, Original-Port = Eth-Trunk100, Flapping port = XGE1/0/1. Please check the network accessed to flapping port.

Possible reasons:

Client's movement-A simple MAC drift appears in the log at this time, with no effect

However, if there are a large number of MAC drift logs, showing the same mac drift, there may be a two-layer loop, or suffer from *, check the status of stp, MAC drift table

Display mac-address flapping record

Move-Time VLAN MAC-Address Original-Port Move-Ports MoveNum

SJV 2011-08-31 17:22:36 300 0000-0000-0007 Eth-Trunk1 Eth-Trunk2 81

2011-08-31 17:22:44

You can configure the maximum number of MAC that can be accessed by configuring the same priority of MAC address that cannot be overridden and statically bound.

8. The veneer is not working properly.

Display device

CE12808's Device status:

Slot Card Type Online Power Register Alarm Primary

1-CE-L48XS-EC Present On Registered Normal NA

3-CE-L48GS-EA Present On Registered Normal NA

5-CE-L48GT-EA Present On Registered Normal NA

9-CE-MPUA Present On Registered Normal Master

10-CE-MPUA Present On Registered Normal Slave

11-CE-CMUA Present On Registered Normal Master

12-CE-CMUA Present On Registered Normal Slave

13-CE-SFU08A Present On Registered Normal NA

14-CE-SFU08A Present On Registered Normal NA

15-CE-SFU08A Present On Registered Normal NA

16-CE-SFU08A Present On Registered Normal NA

17-CE-SFU08A Present On Registered Normal NA

18-Present Off Unregistered-NA

PWR1-PAC-2700WA Present On Registered Normal NA

PWR2-PAC-2700WA Present On Registered Normal NA

PWR3-PAC-2700WA Present On Registered Normal NA

PWR4-PAC-2700WA Present On Registered Normal NA

PWR5-PAC-2700WA Present On Registered Normal NA

PWR6-PAC-2700WA Present On Registered Normal NA

PWR7-PAC-2700WA Present On Registered Normal NA

PWR8-PAC-2700WA Present On Registered Normal NA

FAN1-FAN-12C Present On Registered Normal NA

FAN2-FAN-12C Present On Registered Normal NA

FAN3-FAN-12C Present On Registered Normal NA

FAN4-FAN-12C Present On Registered Normal NA

FAN5-FAN-12C Present On Registered Normal NA

FAN6-FAN-12C Present On Registered Normal NA

FAN7-FAN-12C Present On Registered Normal NA

FAN8-FAN-12C Present On Registered Normal NA

FAN9-FAN-12C Present On Registered Normal NA

FAN10-FAN-12C Present On Registered Normal NA

FAN11-FAN-12C Present On Registered Normal NA

FAN12-FAN-12C Present On Registered Normal NA

FAN13-FAN-12C Present On Registered Normal NA

Display switchover state

Switchover State: Ready

Switchover Policy: Board Switchover

MainBoard: 9

SlaveBoard: 10

It is recommended to check whether the veneer is plugged in or replaced. There may be no plug-in card.

Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.