Network Security Internet Technology Development Database Servers Mobile Phone Android Software Apple Software Computer Software News IT Information

In addition to Weibo, there is also WeChat

Please pay attention

WeChat public account

Shulou

Siemens S7200 PLC SMS Application Scheme

2025-02-23 Update From: SLTechnology News&Howtos shulou NAV: SLTechnology News&Howtos > Network Security >

Share

Shulou(Shulou.com)06/01 Report--

Overview of Siemens PLC SMS Scheme

In order to realize unattended, when the equipment breaks down, the personnel on duty are notified by SMS or dialing, which has been widely used in the PLC control system. The traditional way of implementation is generally through the communication port of PLC to connect the SMS cat, through the free communication protocol of PLC, to control PLC to send SMS. The drawbacks of such schemes are:

1. The program is complex, need to be familiar with PLC free protocol programming, AT instruction set, if you need to send Chinese text messages, but also need UNICODE coding, very troublesome, therefore, the use of SMS cats, generally only achieve a simple alarm.

two。 Poor reliability, many ordinary SMS cats are not designed for the harsh industrial environment, mostly using domestic modules or dismantling TC35I modules, easy to crash, no response and so on.

New solution:

1.PLC does not need to write any program, just simply configure the GRM200 module. SMS functions include Chinese SMS alarm, SMS query PLC register, SMS modification register.

two。 Directly supported PLC includes Mitsubishi, Siemens S7-200, S7-300, OMRON, Delta and standard MODBUS master-slave protocols.

3. You can also connect Panasonic PLC, Yonghong PLC, Schneider PLC,AB PLC and other PLC through modbus communication.

4. It can be used as MODBUS slave and touch screen, and can be directly connected by configuration software to realize the function of short message.

5. The industry's first industrial-grade SMS alarm controller that has passed the Saibao anti-interference test certification.

6. The high priority alarm can be set to be confirmed by SMS. If the person on duty does not confirm the alarm, the alarm message will be continuously sent to the person on duty according to the set time interval. And you can first dial the mobile phone of the person on duty, and then send text messages.

PLC short message controller product details: http://www.shyk.com/pdetail.asp?baseid=3&secondid=3002&id=224

Hardware requirements and connections:

This scheme only needs one Siemens PLC and one giant control GRM200 module. You can complete the PLC SMS alarm by configuring GRM200.

Connect the PPI communication port of S7-200 to GRM200 directly. Giant control GRM module supports multi-master PPI protocol, on the same communication port, you can also hang the touch screen, do not occupy the communication port alone! The connection diagram is as follows:

The figure above is an example, using PPI multi-master protocol, GRM200 as master station 1, touch screen as master station 0 and PLC as slave station 2. The three baud rates are required to be the same.

The bus can also hang more Siemens PLC, requiring that all Siemens PLC slave addresses are different and the baud rate is the same.

GRM200 software configuration:

This scheme only needs to configure the GRM200 module and can be configured by using USB and GRM200 connection.

The main results are as follows: (1) the method of using GRM200 is similar to that of configuration software, as long as the corresponding PLC communication protocol is selected, GRM200 can actively collect PLC data.

(2) configure the PLC register to be read and the corresponding address. As shown in the following figure, GRM200 will actively read the data of S7-200VW100.

(3) configure the alarm condition, the temperature value VW100 > 50, and the short message module sends short messages to the personnel on duty.

(4) configure the content of alarm SMS.

If the alarm is established, the text message sent is: 2013-07-10: 12:30:12 the temperature is too high!

(5) configure users to receive SMS messages

(6) configure the mobile phone number for receiving SMS messages

PLC models are supported:

1:MODBUS host protocol, support Xinjie and other domestic PLC.

2:MODBUS slave protocol, can connect Wellen, Siemens and other touch screens.

3:PPI protocol supports Siemens S7-200PLC.

The 4:MPI protocol supports the communication of Siemens S 7-300 S 7-400 PLC.

5: Mitsubishi FX series PLC protocol, supports all models of FX series PLC.

6: Mitsubishi Q series PLC protocol.

7: OMRON HOSTLINK protocol.

8: Delta PLC agreement.

9: you can also connect Panasonic PLC, Yonghong PLC, Schneider PLC,AB PLC and other PLC through modbus communication.

Using GRM200 SMS to control reminder, you can start and stop the device remotely at any time, which has more flexibility and concealment than fixed term reminder. At the same time, GRM200 has the function that can not be broken or removed by users, so it can achieve highly reliable payment.

1: high reliability, can not be released. GRM200 has timing, conditional execution and other scripts, can be part of the PLC logic and GRM200 execution, even if the PLC is cracked, can not remove the demand. The program of the GRM200 module itself can only be downloaded, not uploaded, and the program cannot be changed after it can be locked.

2: the module itself has its own analog and switch input and output, which can be used with PLC logic to save the analog expansion module of PLC and better achieve the effect of secrecy.

3: if the user unplugs the communication line, it can be set to stop the machine after being asked to pay for it.

4: if the user unplugs the antenna, it can be set to stop the machine after being asked to pay for it.

5: if the user removes the SIM card, it can be set to stop the machine after being urged to pay for it.

6: the user changes to another SIM card, which can be set to stop the machine after being asked to pay for it.