This article shows you what is the cable layout principle in the construction of the server room, the content is concise and easy to understand, it can definitely brighten your eyes. I hope you can get something through the detailed introduction of this article.
There are many useful equipment in the server room, and their location and order should be determined according to the size and requirements of the computer room, so the use of electrical equipment must be connected by cables, and the placement of cables should not only be beautiful, but also safe and reliable. This must let the computer room cable cloth comply with certain standards, in this standard reasonable layout, in order to meet the requirements of computer room construction. The cable layout standards in the computer room are as follows:
The layout standard of network cable includes the following aspects:
(1) pay attention to safety when wiring
(2) the wire should be arranged in grooves, and should not be arranged at will.
(3) Network cable should not be mixed with optical fiber.
(4) Network cable should not be mixed with strong power supply.
(5) set aside a certain distance so that the network cable can be tied to both sides of the rack.
(6) it should be fixed with a tie within a certain length.
(7) circle the remaining network cables, tie them up and place them on the top of the server or on the inside of both ends of the rack.
The arrangement standard of optical fiber includes the following aspects:
(1) do not look directly at the TX end of the optical fiber and or optical module.
(2) the optical fiber should be arranged in a wire slot, and the switch end should use a cable rack, so do not arrange it casually.
(3) Optical fiber should not be mixed with network cable.
(4) Optical fiber should not be mixed with strong power supply.
(5) the bending degree of optical fiber should not be too large.
(6) Optical fiber cannot be tied with hard tape, but should be bound with adhesive tape.
(7) when inserting the optical fiber, do not touch the connector of the optical fiber with your hand.
(8) the remaining optical fiber should be wound and placed on top of the cabinet.
The layout standard of power cord includes the following aspects:
(1) the power cord interface must be plugged into the end.
(2) the power cord should be fastened with straps when bundling.
(3) Don't tie the head and tail of the power cord too tightly, leaving a little gap.
(4) the power cord should be straightened and straightened, not knotted.
(5) it is not allowed to look at the connector of the power cord from the appearance.
(6) the power cord should be symmetrical up and down.
The above content is what is the principle of cable placement in the construction of the server room. Have you learned the knowledge or skills? If you want to learn more skills or enrich your knowledge reserve, you are welcome to follow the industry information channel.
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.