What is the new way of building server room and air conditioning energy saving?

2025-03-26 Update From: SLTechnology News&Howtos shulou NAV: SLTechnology News&Howtos > Servers >

Share

Shulou(Shulou.com)05/31 Report--

Today, I will talk to you about the new ways of building server rooms and saving energy in air conditioning. Many people may not know much about it. In order to make you understand better, the editor has summarized the following contents for you. I hope you can gain something according to this article.

Nowadays, energy shortage is a global problem, and energy conservation has become the only way for the development of data center. In recent years, with the rapid development of Internet and other new technologies, the construction of server data center is in full swing.

1. For refrigeration equipment

In general, the air conditioning system is designed according to the maximum load plus 20-50% reserved load. In actual operation, the air conditioning system does not reach full load, and the system has a lot of redundancy. Therefore, the air conditioning system needs:

(1) reduce unnecessary redundant air conditioning load

(2) invalidation of invalid use can reduce supply.

(3) the cooling capacity of using natural fresh air for cooling effectively.

2. Simple refrigeration setting of air conditioning system.

(1) increase the temperature setting value of the refrigeration system. (the setting point should not be lower than the value required to maintain the inlet temperature of the equipment.)

(2) set the return air temperature properly.

(3) change the uninterrupted operation mode of air conditioner for 7 × 24 hours to intermittent operation mode.

(4) strengthen the sealing performance of the computer room and make rational use of the curtains to adjust the temperature in summer (empirical data show that usually the curtains can adjust the temperature of about 10 ℃)

(5) in the computer room with high energy consumption of adding / dehumidifying, we can consider adding special adding / dehumidifying equipment.

3. Some tips

(1) properly increase the temperature of the air conditioner without affecting the cooling effect.

(2) set the low temperature shutdown function, because the air conditioner consumes about 50W per hour when the compressor is not working. Turn off the machine at the right time, which not only saves electricity, but also prolongs the service life of the air conditioner.

(3) to link the air conditioning system with the fresh air system, the computer room mainly relies on the air conditioning to maintain the internal temperature. In winter or night, it makes use of the temperature difference between the base station indoor and outdoor to bring in the cold air outside the computer room, and at the same time radiates the heat from the computer room, which can reduce the temperature in the computer room and save the power of air conditioning. That is, stop the cooling of the air conditioner at a certain temperature and turn on the fresh air system.

After reading the above, do you have any further understanding of the new ways of building server rooms and air conditioning energy saving? If you want to know more knowledge or related content, please follow the industry information channel, thank you for your support.

Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.

Views: 0

*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.

Share To

Servers

Wechat

© 2024 shulou.com SLNews company. All rights reserved.

12
Report