The requirement scheme for the construction of wisdom archives (can be used as a sample of bidding)
Mainly related to the system:
Temperature and humidity Monitoring system of Wisdom Archives
Disinfection and purification system of Wisdom Archives
Fire Protection Monitoring system of Wisdom Archives
Security Monitoring system of Wisdom Archives
Water leakage Monitoring system of Wisdom Archives
Air quality Monitoring system of Wisdom Archives
Automatic constant temperature and humidity Disinfection and purification system for Wisdom Archives
Big data Cloud platform Construction system of Wisdom Archives
Development Map of Environmental Monitoring system for Wisdom Archives
(1) Technical requirements
Follow the standard
"× × Archives Law"
Measures for the implementation of the Archives Law
Implementation outline of National Archives Informatization Construction
Implementation opinions of the General Office on strengthening the Development and Utilization of archival Information Resources
Interim measures for the Administration of filing of Electronic official documents
Format of official documents of State Administrative organs GB/T 9704-1999
Rules for the arrangement of Archives DA/T32-2000
General requirements for the composition of Scientific and technological Archives GB/T2-2000
GB8566-88 computer Software Development Specification
Guide to the compilation of GB8567-88 computer system Development documents
Guide to the compilation of requirements description for GB9305-88 computer Software
Guide to the documentation of GB9386-88 computer Software testing
1 Technical requirements
1.1 Technical requirements of integrated intelligent management system for archives warehouse
1.1.1 overall design requirements of the system
The system needs to adopt advanced technology in warehouse environmental management and security management, as a strong backing for the safe storage of physical archives, and follow the advanced concept of decentralized control and centralized management. strengthen the important role and core position of the system in the archives warehouse management, and effectively protect the physical archives.
1554283708 (1)
3D main interface
Secondary interface
1554284058 (1)
Integrated intelligent manager
1.1.2 system design principles
Versatility
The design of the system should conform to the national design standards.
Reliability.
The equipment should have a perfect authority management system, and the parallel structure of Cramp S and BPX S should be adopted to improve the operation efficiency of the system and make the user experience better.
Stability.
The system should have industry-leading technology, leading manufacturing and leading brands; strict development process, factory inspection, raw material quality control to a large extent to ensure the high stability of products
Security.
The system should have a perfect system log system, login users in the login system, access functions, operation functions are all-round log recording. Ensure that the operations done by users in the system are documented, and ensure the security of archival data.
Maintainability
The main equipment should adopt modular design to facilitate the maintenance and handling of faults.
Expandability
The system should be Cramp S and Bamp S parallel structure. Each of the two architectures should do their best and give full play to their respective advantages, so that the running efficiency of the system can be greatly improved and the user experience can reach 00.
Economical efficiency
In the overall design of the system, the equipment capacity should be designed reasonably and the equipment cost should be reduced.
1.1.3 system basic platform
System architecture: the system adopts the parallel system architecture with the warehouse as the core and the service-based Cmax S structure and the BPX S structure. The file management function depends on the Cmax S architecture, and other functions support the Bamp S architecture. The system is composed of server server and user client.
Windows services: the system needs to adopt a service-based model. The service is built and run on the Windows system, including Http protocol site service and SOCKET-based network communication service. As a HTTP web site, the service itself is required to support Web access.
System interface form: all service interfaces of the system are published in the form of WebServices.
The system is required to use special technology to maintain the long-term effectiveness of the connection between the server and the client.
System log system requirements: login users in the login system, access functions, operation functions for a full range of log records.
System plug-in: the system encapsulates video preview web page OCX plug-in, bar code print web page OCX plug-in. For web programs or third-party web programs to call.
Client interface style requirements: the client consists of vertical navigation menu, administrator status interface, horizontal function page tags composed of menu structure, fast switching, environmental monitoring, video surveillance, dense rack control interface for independent tags.
System server functional requirements
1. Support the system's HTTP server, FTP server port settings, system file storage path settings.
two。 Support server start, stop and restart.
3. The server interface is hidden in the taskbar in the lower right corner of the Windows desktop.
4. Support SMS sending parameter settings and email sending parameter settings.
5. Support LED LCD TV parameter setting.
6. Support to create, manually back up the database, and you can test the database connection directly.
7. Support the integration of the data after the transformation of the existing office system docking and data exchange.
1.1.4 Environmental management
1.1.4.1 Warehouse environment overview function
The interface centrally displays the temperature, humidity and alarm status data of all warehouses. The data is displayed in separate screens in the warehouse, supporting double screens, four screens and nine screens at the same time, and the content of the screen can be switched.
The temperature and humidity data are displayed in the form of a combination of graphics and data; the temperature and humidity is normal, the temperature and humidity is lower than the standard, and the temperature and humidity are higher than the standard and displayed in different colors.
The icon indicates whether the alarm goes to the police or not.
Display the warehouse name in an obvious location, and click the warehouse name to open the environmental monitoring page of the corresponding warehouse.
1.1.4.2 Environmental Monitoring function
The display interface requires that the background is the actual layout drawings of the warehouse, and the content is all the equipment and data in the warehouse. Drawings can be uploaded and replaced directly.
The manual and automatic working modes can be switched directly, the manual mode equipment runs according to manual control, and the automatic mode equipment operates according to the set parameters.
Support to directly turn off the corresponding acousto-optic alarm.
The interface is divided into normal mode and editing mode. In normal mode, the location, quantity and parameters of the equipment are not allowed to be changed to prevent the misoperation of the user.
The edit mode supports synchronizing the configuration information from the controller or synchronizing the controller configuration information with the server to avoid repeated operations.
Support to directly add or remove warehouse environment management devices in the interface, and display their real-time data.
Support to set device name, number, upper and lower limits of temperature and humidity.
1.1.4.3 Monitoring and recording function
Support temperature and humidity data query, curve table display, detailed data display and printing.
Support curve report generation by month, week and day.
The temperature and humidity records can be queried according to the equipment type and time interval, and the recording time of the data can be displayed and the query results can be printed.
Support by time query temperature and humidity abnormal records, display alarm event information and time, support printing query results.
1.1.4.4 Task scheduling function
Support the setting of regular operation strategy for warehouse environment alarm, adjustment and purification tasks, and support setting start-stop time, equipment number interval and working date.
Supports two-way synchronization of task scheduling with task scheduling on the environmental management controller.
1.1.5 dense rack management
1.1.5.1 frame control function
Support the remote viewing and control of the frame body, graphically display the open or closed status of the frame body, and the prohibition and alarm status of the frame body can be displayed directly. Support and control the corresponding frame to move to the left, right, stop, prohibit and lift the ban, open and close the shelf automatically.
Support frame manual control ventilation, support the display of temperature and humidity data in the current area.
Support to diagnose whether the communication status with the dense rack fixed column is normal.
When the frame body has operation instructions, the corresponding surveillance video live broadcast is supported, and the status of the frame body can be observed intuitively.
1.1.5.2 dense rack environment monitoring function
Support the query of temperature and humidity data collected by dense rack, curve table display, detailed data display and printing.
Support curve report generation by month, week and day.
1.1.6 Monitoring and management
Video display and query
1) support parallel preview and playback of different channels under multi-image segmentation
2) support synchronous playback on 4-8-16
3) support tag definition, query and playback of video files
4) support intelligent search for custom areas of video scenes during playback
5) support querying, playback and backing up video files by event
6) support video file reversal function
7) support automatic round-robin and round-robin time setting function of monitoring point screen
Alarm response and linkage
Support to maintain a long-term connection with various video monitoring points, and when receiving the infrared alarm message sent back by the warehouse environmental service, you can respond immediately to start recording and take pictures when you give an alarm. When the alarm picture is captured, the short message function module is called to send the reminder message, and the mail function module is called to send the alarm picture.
Alarm playback
Alarm playback is that once the alarm occurs, the camera associated with the alarm immediately starts the video recording, and the alarm video file is listed on this page, and double-click the video file to play it directly.
The image is recorded through a video recorder or digital image storage device for later use.
Provide free interface for the system and cooperate with the system construction.
1.1.7 guidance Management of Intelligent Warehouse
Support to add and remove intelligent guidance devices
Support to modify and delete the configuration information of the selected intelligent guidance device
Support automatic reading of relevant data in the system (such as temperature and humidity, air quality, alarm information, etc.) and automatic display.
1.1.8 Parameter configuration function
Basic parameter settings: support editing using unit name, URL, server IP and port.
Database parameter settings: support setting database ip, name, account, password, support test connection function.
Configuration server function: support system service parameter setting, automatic recording time setting, video recorder parameter setting, short message alarm parameter setting, mail server parameter setting, service management function.
Support dense rack, area intelligent controller, video surveillance equipment parameter setting.
Support dense rack setting data query, add, filter, sort, support printing and export; support ventilation linkage function settings.
Support the addition, deletion and modification of system accounts.
Support the allocation of account permissions, the system supports the allocation of account permissions according to functional modules, different accounts can operate different functional modules; support the allocation of account permissions according to the type of operation, view, edit, delete, equipment operations can be authorized separately.
1.1.9 Log management function
Log user and ip login information.
The exception in the system service is logged to analyze the system failure.
1.2 Environmental equipment requirements
1.2.1 area Intelligent Controller
The regional intelligent controller should have the function of centralized control of the main equipment in the archives warehouse, adopt a 7-15-inch integrated industrial touch screen based on Windows CE system, collect and display the temperature and humidity sensor information in the warehouse through wireless bus control technology, and control the operation of constant temperature and humidity purification equipment in the warehouse. Communicate with the server through the network to complete the transmission and recording of information.
Parameter requirements:
Equipped with not less than 7-inch touch integrated LCD screen
Display temperature and humidity information and equipment operation status in graphic and list mode
Support for history display
Support web access, support TCP/IP access
The memory is not less than 512m
Interface: supports RS-232, RS-485, USB, network port, audio output, etc.
Supports communication with the server through the TCP/IP protocol
Collect information through radio frequency technology and control the operation of the equipment, eliminating wiring construction and maintenance work
The operation of the equipment can be controlled automatically according to the upper and lower limits of temperature and humidity and environmental parameters. Manual control is also supported.
Support to query temperature and humidity records, and generate temperature and humidity reports according to month, week and day
The background map of the warehouse can be changed freely through the Web access side.
Support temperature and humidity alarm and alarm query
Temperature, humidity and environmental objectives can be set to support alarm deployment and withdrawal according to the time period.
Support through the web page to directly access the area controller, view the status of the device, control the operation of the device.
1.2.2 Air quality cloud meter
Air quality cloud measuring instrument should be equipped with intelligent single chip microcomputer data processor
The collection of ambient temperature and humidity, carbon dioxide, PM2.5, PM10 and air quality TVOC should be supported.
Support wifi data transfer mode
Support custom management of user-level permissions
Support remote access from smart terminals and mobile clients, query and detect regional environment data
Support data analysis and collation and intuitive display in the form of charts
Support wall-mounted installation
Communication mode: 485MHz wireless communication and RS485 wired transmission should be supported.
Temperature range:-40 to 80, accuracy ±0.3 ℃
Humidity range: 0 to 99.9, accuracy ±2%RH
Carbon dioxide range: 0~5000ppm accuracy ±75ppm ±3%
TVOC range: 125~600ppb resolution 1ppb
PM2.5 range: 0.3 μ m ~ 2.5 μ m ~ 10 μ m 00 small precision 0.3 μ m
1.2.3 constant humidity purification all-in-one machine
Constant humidity air purification automatic regulation requirements: through the constant humidity purification all-in-one machine to control warehouse humidity, air quality, so that the warehouse environment to meet the requirements of storage files.
1.2.3.1 basic requirements
Amount of humidification (Kg/h): 7: 8
Amount of dehumidification (Lram 24 h): 60-120
Applicable space (m ²): 90mm 120
Air volume (m ³/ h): 1600-2000
Power: ≤ 1300W
Noise: ≤ 55db
Power supply: 220V/50HZ
Water tank volume: ≥ 45L
Water filling mode: fully automatic
1.2.3.2 requirements for environmental protection and energy saving:
The specific surface area of wet film is more than 1:66 and the steam-water saturation is higher than 60%.
The wet film vaporization humidification is equal enthalpy humidification, the peripheral parts of the wet film shall be made of 304L stainless steel, and the water supply pipe fittings shall be made of industrial grade PVC-U pipe.
1.2.3.3 structural requirements
Adopt the way of circulating water humidification. And must have automatic defrosting function.
Humidifying pump and drainage pump shall adopt submersible pump, and the outlet of pump shall adopt pluggable and easy maintenance interface.
1.2.3.4 Intelligent control requirements
The equipment should adopt not less than industrial grade anti-interference greater than or equal to 7 inch WINCE system screen control dehumidification, humidification, purification and other functions.
It is required that the temperature, humidity, PM2.5, TVOC and CO2 data of the environment can be detected and displayed on the main screen.
It is required to show the various states of the water tank, including water level, leakage, intake valve.
Automatic control of humidification and dehumidification according to humidity requirements, automatic control of electronic purification according to TVOC and PM2.5
It is required to be equipped with cleaning, wind speed adjustment and leaf swing control functions.
Historical data of temperature, humidity, PM2.5, TVOC and CO2 can be recorded for not less than one year.
Support to generate curve reports by year, month and day
Support for simplified Chinese and English
Support Modbus communication protocol, RS485, remote monitoring port
1.2.3.5 purification technical requirements
The air purification system needs to adopt more than six-stage purification mode, which has many functions such as dust removal, sterilization, removal of TVOC, removal of sulfur dioxide, nitrogen dioxide and so on.
A rough filter made from Al-Ni alloy corrugated mesh shall be adopted, and the filter grade shall be G4.
Adopt replacement-free electronic electrostatic dust removal device
1.2.3.6 overall requirements
The grounding is good and the grounding resistance is less than 10 ohms
The equipment must have thermal insulation and noise reduction device, and the noise of the whole machine is not more than 56dB; in order to ensure that the instant noodles of the equipment are free of condensation, the inner wall of the equipment must be insulated, and the thermal insulation material is B2 grade polyurethane material not less than the thickness of 30mm.
The equipment must have a perfect alarm system to facilitate equipment fault diagnosis and maintenance, and should be equipped with high temperature, high humidity, low temperature, low humidity, water leakage, compressor over-current, over-pressure, under-pressure, fan loss alarm lamp function.
1.2.4 Water cart
90L mobile water tank, equipped with universal wheel, built-in water pump
1.2.5 Intelligent Control Module
Wired-wireless transmission should be supported
Cable should support RS485 communication protocol
High transmit power is 17dbm (50mW)
The frequency band of wireless communication is 472-485MHz.
It supports the communication between temperature and humidity transmitter, serial port learning infrared remote controller, leakage sensor, infrared double detection sensor and regional intelligent equipment.
1.2.6 Serial Port Learning Infrared remote Controller
Support 38K or greater distance infrared learning, special long instruction learning
It is required to match 99% of the mainstream brand infrared remote controllers on the market and convert them into serial data output. On the contrary, the data received from serial ports can send the same infrared signal through infrared diodes.
Operating temperature range:-30 ℃ ~ 85 ℃
Infrared carrier frequency width: 31KHZ ~ 80KHZ
Support direct control of upload and download or serial port instructions
Power failure data will not be lost.
Standard RS485 interface is supported.
1.2.7 leakage sensor
Detection cable: configure ASC2100 two-core detection cable (or detection electrode)
Test cable length: 00 big connectable cable length is 500 meters
Sensitivity: 2mm-100mm adjustable (tap water)
Response time: less than 1 second
Power requirements: 12-24V DC / AC power supply
Relay output: 2SPDTjin60VDC or 125VACjin1A rating (normally on and off)
1.2.8 leakage sensing line
Distributed near the outlet point of the archives warehouse, two-core spiral detection cable
1.2.9 Infrared double identification sensing equipment
Using microwave and infrared double detection technology, built-in temperature compensation and microwave anti-jamming function
Detection range: ≥ 7.6m × 7.6m
Sensitivity: normal walking speed 2-4 steps within the detection range
Operating temperature:-25 ℃-65 ℃, 5% Murray 95% relative humidity (non-condensing)
Anti-white light interference: 8000Lux.
1.2.10 burglar alarm light
A set of sound and light alarm equipment, DC12V\ 120db\ red
1.3 requirements for intelligent management upgrade of dense rack
1.3.1 General requirements
All the intelligent dense shelves of archives warehouse should have the function of integrated management, which can integrate manual, electric, computer integrated management system, mobile terminal and network remote control, which are independent of each other and protect each other, and are managed by the integrated intelligent management system of archives warehouse. It should be composed of computer integrated management system, electronic control system and mechanical transmission control system. And can be humanized design as the concept, intelligent control system and network management mode as the basis, to achieve macro-automatic frame control, automatic human body protection, environmental regulation, data disorderly storage and orderly management.
1.3.2 Intelligent control requirements
1.3.2.1 basic functional requirements
Manual control function
The intelligent dense rack should allow manual control, and each row of dense rack should be equipped with a rocking handle, which, like the traditional dense rack, can be opened or closed by shaking the handle.
Electric control function
The mobile column control screen shall have operation buttons with dense shelf control functions such as locking, unlocking, stopping movement, moving to the left, moving to the right, closing the shelf, ventilation, automatic opening of the shelf, and can operate the shelf through the corresponding button; through the fixed column touch screen to control various operations such as locking, unlocking, stopping moving, moving to the left, moving to the right, closing the shelf, ventilation, automatic shelf opening and other operation settings, data management query, and other operations. When the frame body moves, the movement column control screen should have an interface that switches to display only the frame movement pointing arrows, text prompts and three-dimensional patterns of the frame body.
Computer control function
The computer remotely controls the operation of moving each frame to the left, moving to the right, stopping, prohibiting, unlocking, closing the frame and so on.
PDA control function
PDA remotely controls various operations such as moving to the left, moving to the right, stopping, prohibiting, unlocking, closing, data management, query and input of each frame.
Motor function
The motor power is not less than 120W.
It has the function of running speed setting and the function of frame slow start.
With automatic lighting function
24V LED cold light strip lighting is adopted.
It has the function of non-contact detection.
It has the function of human body sensing open shelf.
When the person stands in front of the mobile column for more than 5 seconds, the corresponding column opens automatically.
With archival lighting guidance function, voice broadcast guidance function and remote emergency locking function.
Has the display function of serial number digital tube.
The display function of the serial number digital tube requires that it can be arranged and numbered arbitrarily. No less than 5-digit 1.8-inch digital display mode.
It has the function of temperature and humidity detection and regular ventilation, the function of setting the upper and lower limit of temperature and humidity and the function of smoke alarm.
Mobile column display control function
Using no less than 8-inch true color touch LCD screen, the touch screen can display the area series number, temperature and humidity value, frame status, data name, location information, the touch LCD screen is required to have left, right, stop, prohibition, frame, query function buttons, as well as parameter setting menu. the running speed of the motor can be set directly in the parameter setting menu. Can set parameters greater than or equal to 15.
Fixed column display control function
Adopt not less than 10.4 inch integrated touch display host. The top of the screen should display function buttons such as prohibition, stop, automatic shelf opening, shelf closing, ventilation, query, open shelf list, multi-channel, setting, closing and so on. The main interface of the fixed column can intuitively display the dense frame column; when the frame body moves, it can display the running state in the form of animation; in the middle of the screen, there should be two arrow buttons in opposite directions to control the movement of the frame body left and right, and the center of the screen should be able to display the running status of the frame body and the temperature and humidity information in real time. When opening the shelf, the file name, file bar code, address bar code, storage mode and other information should also be displayed at the bottom of the screen. The software comes with WebService, and remote computers and mobile phones can directly access the fixed column to obtain the real-time frame picture information of the fixed column and the web page control frame body.
It has the shelf function, the multi-channel function, the temperature and humidity display function, the network management function and the control interface function.
With independent network management function
Main control column configuration integrated control host, using Wince6.0 version operating system, stable and reliable performance, support site publishing function, can issue fixed columns without configuring the server to access the master station, terminals in the local area network (including mobile devices) can control the movement and stop of the frame body by accessing the fixed column ip through web page access, and can view the status of the mobile column.
With open-shelf list function, section information setting function and maintenance information prompt function
Infrared protection function
1.3.2.2 functional requirements for security protection
The front panel and aisle adopt infrared protection technology to protect the safety of personnel in the frame. And the status indication on the control screen changes from green to red, and the aisle with the word red is prompted, and the aisle indicator light of the mobile column control screen turns red.
Chassis grating protection function
Should have chassis raster protection function, install raster sensors in the first and last columns of the file storage area, file inspection personnel enter the dense rack, prohibit the dense rack movement operation, and protect the safety of personnel.
Motor blocking protection function
When the motor has mechanical failure or overload in the process of operation, the motor blocking protection device will automatically cut off the power supply of the motor, and after troubleshooting, it can automatically resume operation.
Run the timeout protection function
When the mechanical components are loose or skidding, it will cause the motor to run for a long time. It should have the protection function of overtime operation: when the running time (should be adjustable) exceeds, it can stop running urgently. When a run timeout occurs, a run timeout prompt is displayed on the control screen, and the run time indicator on the mobile column control screen lights up and turns red.
Leakage protection function
There are special circuit breakers in the power circuit and the operation circuit, such as when leakage or overcurrent occurs, the circuit is immediately stopped and the circuit is cut off. The electrical circuit must have a reliable short-circuit protection device, and the insulation resistance between the short-connected power circuit and the protection circuit (including the machine base) should be greater than 1m Ω. The insulation resistance of the wire shall not be less than 20m Ω.
Overload protection function
When the average speed of the motor is destroyed, the circuit is automatically overloaded.
Motor locking function
When there is someone in the frame, the motor is locked automatically, and the frame is forbidden to move, so as to prevent the injury of the personnel in the frame caused by the misoperation of other personnel.
Anti-clamping protection function
To achieve a safe dense frame anti-clamp protection function, in the case of all sensor failure, can be reliably stopped. And the anti-clamping protection parameters can be set on the setting interface in the mobile column control screen.
Cable layout requirements
The transmission cable shall be overhead and shall not be wound or knotted, and there will be no tension when the cable is opened to a large position. The cables must conform to the national standards.
Mechanical lock function
After the mechanical lock is locked on the mobile column, the frame body cannot be moved, the mechanical lock is displayed in the control screen, and the mechanical lock indicator light on the mobile column control screen turns red.
Security locking function
Side column password lock function: should have a security locking function, only the correct entry of the password can be authorized by the system and can operate the dense shelf, other unauthorized personnel can not open the dense shelf to protect the file security.
1.4 requirements for security equipment
1.4.1 access control
Verification method: swipe card, fingerprint, password
Storage capacity fingerprint capacity: ≥ 3000 record capacity: ≥ 100000 card capacity: ≥ 5000
Display screen: ≥ 2.4in HD color screen
Menu language: simplified Chinese
Communication interface: supports TCP/IP and RS485
1.4.2 Network hemispherical infrared camera
Pixels: not less than 2 million
A resolution of not less than 1280 × 960 @ 30 fps is required, at which real-time images can be output.
Video compression techniques such as ROI and SVC are required, with high compression ratio, very flexible processing and ultra-low bit rate.
Progressive scanning of CMOS is required to capture moving images without aliasing.
Support ICR infrared filter automatic switching to achieve real day and night monitoring
Support PoE power supply function
1.4.3 Network hard disk video recorder
Greater than or equal to 8 network video inputs, 2 SATA interfaces
Support HDMI and VGA homologous output, HDMI and VGA output resolution greater than or equal to 1920x1080
Video / capture mode: manual video recording, timing video recording, mobile detection video recording, alarm video recording, dynamic test or alarm video recording, dynamic test and alarm video recording
1.4.4 dedicated hard disk for monitoring
Capacity: no less than 4TB, monitor-grade hard disk.
1.4.5 Network switch
The switching capacity is not less than 32Gbps, and the packet forwarding rate is not lower than 6.6Mpps.
Network standards: IEEE802.3, 802.3uddi 802.3ab, 802.3z, IEEE802.3x, IEEE 802.1Q; support automatic configuration support CLI configuration support Telnet remote configuration support SNMP V1/V2/V3 support RMON support cluster management HGMP V2 support SSH V2 support WEB management features support GVRP protocol
Port parameters: POE powered, 24 10/100Base-TX ports greater than or equal to 2 gigabit Combo ports
Environmental parameters: working temperature 0-50 ℃, working humidity 10-90%, no condensation, storage temperature-5-55 ℃
1.4.6 display
Screen size: 22 inch LCD or greater
Panel type: IPS panel
Response time: 5ms
Resolution greater than or equal to: 1920 to 1080
1.5 requirements for warehouse guidance equipment
1.5.1 LED LCD TV (bracket mounting)
Screen size: 55 inches or greater
Screen resolution: with 4k
Screen ratio: 16:9
Screen brushing rate: with 60Hz
Scanning method: progressive scanning
1.6 system auxiliary equipment requirements
1.6.1 computer
With COM serial port, PCI W10 host, 23-inch LCD greater than or equal to.
CPU:Inteli5 and above
Memory: greater than or equal to 8GB
Hard disk: greater than or equal to 1TB and above
Graphics card: greater than or equal to 2GB or above
Keyboard, mouse
1.6.2 Network switch
Transfer rate: 10/100/1000Mbps
Switching method: store-forward
Backplane bandwidth: greater than or equal to 56Gbps
Packet forwarding rate: greater than or equal to 42Mpps
Port parameter: 24 10/100M/1000Mbps ports or greater
Environmental parameters: working temperature 0-45 ℃, working humidity 20-85% without condensation
1.6.3 SMS alarm
Parameter requirements: SMS alarm message automatic sending module, support leakage alarm, infrared alarm.
1.6.4 Printer
Color laser printing
Print speed: black and white, ≥ 17 pages / min; color: ≥ 4 pages / min
00 High Resolution: resolution ≥ 600x600dpi
1.6.5 UPS
Input voltage range: 115Murray 300V
Rated power: greater than or equal to 3KVA
Battery type: sealed lead-acid battery
The battery life is not less than 1 hour, and the power 1KW
Store not less than eight 12V 38AH batteries
@ @
Beijing Shengshi Hongbo Technology Co., Ltd.
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.