Configuration of APC UPS Network Management Card (Model apc ap9631)

2025-03-29 Update From: SLTechnology News&Howtos shulou NAV: SLTechnology News&Howtos > Network Security >

Share

Shulou(Shulou.com)06/01 Report--

How to configure the IP of the network card?

If the network card is brand new and unused, there are two ways to configure the network card, 1. Use ARP protocol to configure 2. Benefit

Use serial port to configure in hyperterminal

If the network card has been configured and used, you can only use the serial port to configure the network card in the hyperterminal.

A: how to quickly configure network management cards such as AP9617/9618/9619/9630/9631/AP9635 with ARP protocol?

First, the applicable environment and prerequisites are:

1the network management card such as 9631 Accord 9635 is new (factory default) and has not been configured. That is,

After the network management card is inserted into the smart slot of the UPS, the card's status light flashes orange.

2. There is an Ethernet network system available at the installation site. (if not, you can also connect the twisted pair cable of PC directly with PC.)

3. An available Windows computer connected to the network.

Second, specific operation

1. Insert AP9617AP9617/9618/9619/9630/9631/AP9635 and other network management cards into the smart slot of UPS, turn on UPS, and check the card's

Configuration statu

2, plug the network cable into the card, connect it to the local area network, and check whether the card's 10x100 Link status light is on. If not, please check the network cable.

3. Turn on the Windows computer that is available for access to the network, change to the command line, and run the following command:

Arp-s IP_address_card MAC_Address_card

For example, we want to assign an address of 159.215.240.22 to the UPS network card, which needs to be entered in the Windows operating system.

Arp-s 159.215.240.22 00-c0-b7-78-ad-90

Input is required in the Linux operating system

Arp-s 159.215.240.22 00:c0:b7:78:ad:90

Note: a label marked MAC Address can be found on network management cards such as AP9617AP9617/9618/9619/9630/9631.

The IP address is free and available.

4. Run Ping IP_Address first to check whether the configuration is effective. Note that the IP address of the Windows computer must be the same as the one previously assigned to UPS.

The IP address is on the same network segment.

For example, in the Windows operating system

Ping 159.215.240.22-l 113

In the Linux operating system

Ping 159.215.240.22-s 113

5, and then run telnet IP_Address

For example, telnet 159.215.240.22

6. Modify the specific parameters of the login card: the default User Name and Password are apc.

If AP9617AP9617/8/9, enter matching parameters such as Subnet Mask and Defa ult Gateway in the Network- > TCP/IP menu.

If it is AP9631/AP9631/AP9635, after logging in, enter the command:

> tcpip-s # where subnet musk is the subnet mask, such as 255.255.255.0

> tcpip-g # where gateway is the gateway

7. Confirm the parameter modification and exit. The card restarts automatically. There is a Web browser to manage the network and verify its configuration.

8, configuration complete

B: how to configure AP9617AP9617/AP9618/AP9619 with computer serial port hyperterminal

1. Use the 940-0024C communication line (included with the network management card) to connect the computer running the terminal emulation program to the UPS.

2. If the serial port of the computer (connecting the 940-0024C communication line) is being used by APC software PowerChute Plus or other programs, please close it

Related procedures. Start the terminal emulation program such as HyperTerminal, and set the serial port parameters to: 2400bps, No Parity, 8 data bits

1 stop bit, and No Flow Control

Note: after modifying the serial port parameters, the setting will take effect after disconnecting and reconnecting the session (connection).

3. After confirming that the above two steps are correct, press enter.

4. Enter User Name and Password, and the default setting is apc.

5. After logging in correctly, the management interface of the network management card will pop up automatically.

The display interface is as follows: (please modify the relevant parameters according to your needs)

User Name: apc

Password: *

American Power Conversion Network Management Card AOS v2.1.1

(C) Copyright 2002 All Rights Reserved Smart-UPS & Matrix-UPS APP v2.1.0

Name: Unknown Date: 12/11/2003

Contact: Unknown Time: 11:47:50

Location: Unknown User: Administrator

Up Time: 0 Days 0 Hours 20 Minutes Stat: P + N? A +

Environment: Threshold Violation Present, Contact Alarms Disabled, Relay

Disabled

Smart-UPS 1000 named: On Line

-Control Console--

1-Device Manager

2-Network

3-System

4-Logout

-Main Menu.-Refresh.-Event Log.

> 2

-Network--

1-TCP/IP

2-DNS

3-Ping Utility

4-FTP Server

5-Telnet/SSH

6-Web/SSL/TLS

7-WAP

8-SNMP

9-Email

10-Syslog

-Back.-Refresh.-Event Log.

> 1

-TCP/IP-

Network not started. Currently making a BOOTP request...

MAC Address: 00 C0 B7 67 37 4C

1-Boot Mode: DHCP & BOOTP

2-Advanced...

-Back.-Refresh.-Event Log.

> 1

-Boot Mode--

1-DHCP & BOOTP

2-DHCP only

3-BOOTP only

4-Manual

-Back.-Refresh.

> 4

-TCP/IP-

Network not started. Currently making a BOOTP request...

MAC Address: 00 C0 B7 67 37 4C

* Changes will take effect on Logout.

1-System IP: 159.215.125.248

2-Subnet Mask: 255.255.255.0

3-Default Gateway: 159.215.125.1

4-Boot Mode: Manual

5-Advanced...

-Back.-Refresh.-Event Log.

> 1

System IP: 159.215.125.248

-TCP/IP-

Network not started. Currently making a BOOTP request...

MAC Address: 00 C0 B7 67 37 4C

* Changes will take effect on Logout.

1-System IP: 159.215.125.248

2-Subnet Mask: 255.255.255.0

3-Default Gateway: 159.215.125.1

4-Boot Mode: Manual

5-Advanced...

-Back.-Refresh.-Event Log.

> 5

-Advanced...

Link is down.

1-Host Name: APC

2-Domain Name: somedomain.com

3-Port Speed: Auto-negotiation

4-Accept Changes:

-Back.-Refresh.-Event Log.

> 4

-Advanced...

Link is down.

1-Host Name: APC

2-Domain Name: somedomain.com

3-Port Speed: Auto-negotiation

4-Accept Changes: Success

-Back.-Refresh.-Event Log.

>

It should be noted that the three parameters of TCP/IP, including System IP,Default Gateway,Subnet Mask, must be set, especially the gateway.

Default Gateway cannot be 0.0.0.0, otherwise the network will become impassable. If you exit HyperTerminal, the network setting is successful.

First use the ping command to check whether the network configuration is successful. If you cannot Ping, please Reset the card. There is a white Reset button on the card.

Click, the card restarts, the restart is only the card re-power up, will not change any existing settings in the card.

C: how to configure AP9630/AP9631AP9631/AP9635/AP9635 with computer serial port hyperterminal

Configure using the 940-0299 communication line:

1. Use the 940-0299 communication line (included with the network management card) to connect the computer running the terminal emulation program to the UPS.

2. If the serial port of the computer (connecting the 940-0299 communication line) is being used by APC software PowerChute Business Edition or other programs

Use, please close the related program. Start the terminal emulation program such as HyperTerminal, and set the serial port parameters to: 9600bps, No Parity

8 data bits, 1 stop bit, and No Flow Control

Note: after modifying the serial port parameters, the setting will take effect after disconnecting and reconnecting the session (connection).

3. After confirming that the above two steps are correct, press enter.

4. Enter User Name and Password, and the default setting is apc.

5. After logging in correctly, the management interface of the network management card will pop up automatically.

User Name: apcapcapcapc

Password: *

American Power Conversion Network Management Card AOS v5.0.1

(C) Copyright 2008 All Rights Reserved Smart-UPS & Matrix-UPS APP v5.0.0

Name: Unknown Date: 02/11/2009

Contact: Unknown Time: 02:13:46

Location: Unknown User: Administrator

Up Time: 0 Days 4 Hours 29 Minutes Stat: P + N + A +

Apc >?

Network Management Card Commands:

? About alarmcount boot cd date

Delete dir eventlog exit format ftp

Help ping portspeed prompt quit radius

Reboot resetToDef system tcpip user web

XferINI xferStatus

Device Commands:

Ups

Apc > tcpip? tcpip?

Usage: tcpip-- Configure and display Tcpip parameters

Tcpip [- I]

[- s]

[- g]

[- d]

[- h]

Apc > tcpiptcpip- I 10.219.10.237i 10.219.10.237

E000: Success

Reboot required for change to take effect

Apc > tcpiptcpip- s 255.255.254.0s 255.255.254.0

E000: Success

Reboot required for change to take effect

Apc > tcpiptcpip- g 10.210.10.1g 10.210.10.1

E000: Success

Reboot required for change to take effect

Attachment: http://down.51cto.com/data/2367724

Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.

Views: 270

*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.

Share To

Network Security

Wechat

© 2024 shulou.com SLNews company. All rights reserved.

12
Report