VSAN Storage performance Test report
Catalogue
VSAN Storage performance Test report. 1
First, the test object. 2
Hardware platform. 2
Test platform. 2
Second, IO Meter test. 2
IO Meter2
Test results. 3
Third, VMware HCI Bench test. 7
VMware HCI Bench. seven
Test results. 7
Fourth, analysis of test results. 9
ITD
2017-5-22
1. Test object
5 machines that have set up VSAN clusters
Hardware platform
Equipment model
A total of 5 nodes
CPU
Memory
Hard disk
The network
Dawning compatible server
E52667 v431
64 GB
SSD 120GB * 1 installed system
PCI SSD 256GB * 1
HDD 1.2TB * 6
HDD 1.2TB does not recognize
10GB SFP+
10 Gigabit network
Layer 3 switch (1)
N9504 10G SFP+ 10 Gigabit Network
Due to compatibility reasons: each server has a 1HDD hard drive that is not recognized. Remove unrecognized hard drives to form a VSAN.
Test platform
Software name
Software description
Remarks
VCenter
VCenter Server 6.5
Virtual machine
Windows Server 2012 R2
IOMeter-1.1.0 for Windows
Performance testing tool
Deploy one Testing VM per node
Mount 8 40G HDD
II. IO Meter testing IO Meter
A performance testing software that is widely used in the storage field, enterprise users relatively approve of the results run through the software; in addition, the software is relatively simple to operate, running on Windows 2008 Universe 2012, graphical interface management
According to official instructions, generally complex large environments do not write more than 30%, and more than 70% of them are basically reading. Only test 4K 30% write / 70% read / 100% random. However, in order to squeeze the maximum performance of VSAN, other different tests are also carried out.
Test result
(VSAN is the 4K disk standard)
VSAN
Test scenario
Total IOPS
Read IOPS
Write IOPS
Average response time (milliseconds)
Average read response time (milliseconds)
Average write response time (milliseconds)
4K 30% write / 70% read / 100% random
58425.26
43819.92
14605.3
10.95
3.60
32.99
4K 100% read / 100% random
292640.74
292640.74
N/A
2.1866
2.186566
N/A
Attach the results of Cisco superconvergence for comparison:
Cisco Super Convergence
Test scenario
Total IOPS
Read IOPS
Write IOPS
Average response time (milliseconds)
Average read response time (milliseconds)
Average write response time (milliseconds)
4K 30% write / 70% read / 100% random
86562.81
60730.04
25832.77
4.4
2.2
9.7
4K 100% read / 100% random
268567.53
268567.53
N/A
1.42
1.42
N/A
The results show that:
In a random test of 4k, 30% write and 70% read, the overall performance of VSAN is about 70% of that of Cisco's super-converged architecture.
In the 4K 100% read test, the performance of the two is similar.
Delay:
Thanks to Cisco's unique network technology, Cisco's response time is lower than that of VSAN.
The overall results show that:
The performance of the Cisco platform is excellent, but VSAN's storage performance as pure software is not poor.
The following screenshots are all VSAN tests:
Other types of VSAN tests are attached:
VSAN
Test scenario
Total IOPS
Read IOPS
Write IOPS
Average response time (milliseconds)
Average read response time (milliseconds)
Average write response time (milliseconds)
4K 100% read
100% linear
283265.96
283265.96
N.A
2.25
2.25
N.A
4 KiB; 75% read; 25% write 0% 100% linear
30393.26
22795.26
7597.99
21.05
2.66
76.20
16 KiB; 75% Read; 0% random
34208.36
25656.46
8551.89
18.70
5.44
58.47
3. VMware HCI Bench testing VMware HCI Bench
This is a tool for mass deployment of virtual machines to verify the IOPS and throughput, latency, CPU footprint and memory footprint involved in deploying multiple virtual machines at the same time
Deploy 20 virtual machines over HCIBench, distributed across 5 VSAN nodes. The software records the creation of 20 VM, which is used to analyze the efficiency of establishing virtual machines.
Test result
Datastore: vsanDatastore
VMs = 20
IOPS = 65134.52 IO/s
THROUGHPUT = 254.44 MB/s
LATENCY = 6.3034 ms
R_LATENCY = 1.4818 ms
W_LATENCY = 17.5573 ms
Testing is done, 20 out of 20 VMs finished test successfully. Please check following files for details:
/ opt/output/results/results20170519021233/vdb-10vmdk-10ws-4k-70rdpct-50randompct-2threads-1495186890/vdbench-vsanDatastore-0-4.txt
= =
Resource Usage:
CPU USAGE = 40.87%
RAM USAGE = 55.98%
VSAN PCPU USAGE = 12.1691%
Attach data from the Cisco Super Fusion platform:
4. Analysis of test results
IO Meter: because the five VSAN clusters benefit from the cache processing of PCI solid state drives, the overall performance has reached 70% of that of the Cisco platform.
HCI Bench: a total of analysis with VMWARE engineers, because there are only 3 Cisco nodes and 5 VSAN clusters, the theory is that the more nodes, the higher the efficiency of IO. The IO of solid HCI Benmark is higher than that of Cisco, but because the network of Cisco platform is optimized, it can be seen that the latency of Cisco platform is relatively low and the performance is excellent. It is tested here that because each machine in the VSAN cluster is configured with only one CPU and Cisco has two each, the overall CPU footprint is higher than that of the Cisco super-convergence platform.
VSAN does not need to configure the management virtual machine on each machine in the cluster like Cisco, it only needs to turn on this function in the software to use, which is simple and convenient to maintain. Cisco integrates the advantages of its own network hardware, resulting in low latency and high efficiency of the entire IO. And Cisco can not compare with VSAN in de-stress, VSAN needs all-flash memory to achieve, but Cisco can achieve it in the case of 1 solid state. The test results show that, although the overall performance of VSAN is better than that of CSI super-convergence platform, it can meet the use of server virtual machine and desktop virtualization.
If the company virtualizes (servers, desktops) in the future, VSAN is a good choice.
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.