This article mainly explains "what problems will arise from neglecting the modernization of data center physical infrastructure". The explanation in this article is simple and clear, easy to learn and understand. Please follow the ideas of Xiaobian to study and learn together "what problems will arise from neglecting the modernization of data center physical infrastructure"!
When it comes to data center operational technology (OT), traditional infrastructure such as power, cooling, and ventilation is much slower to update (typically 10 to 20 years for equipment such as UPS batteries and room air conditioning). But now that OT system design is beginning to be applied to built-in intelligence, digital components, and network infrastructure, prolonged inactivity around modern OT systems carries the risk of downtime and economic losses. In fact, outdated physical infrastructure can sometimes hinder the expected benefits of IT technology updates.
When people neglect to modernize the physical infrastructure of the data center, the following problems arise:
increased operating costs
Data centre infrastructure New equipment is much more efficient than existing equipment. Therefore, traditional equipment is often synonymous with higher energy consumption. Taking uninterruptible power supplies (UPS) as an example, when compared to modern UPS power supplies (96% efficiency) with the same load characteristics (88% efficiency) as traditional UPS power supplies, the energy consumption cost of the original UPS power supply (additional energy cost due to inefficiency) is nearly $400,000 more over 10 years of operation. In fact, some UPS power supplies can achieve 99% efficiency when operating in eco-mode. The same is true for cooling facilities, where traditional cooling facilities consume more power in data centers. The new cooling system uses less energy, thereby reducing CO2 emissions.
System reliability degradation
When determining system reliability, it is important not to confuse the reliability of individual power supply components with the reliability of the power supply system. The reliability of a power system depends on its weakest link. If the data center infrastructure isn't modernized in eight to 12 years, there are still a lot of weak spots, and the question isn't whether it will fail, it's when. Existing data centre infrastructure equipment requires additional time, effort and expense to support. For example, parts inventories decrease over time and spare parts cost more. The mean time to repair (MTTR) of data centers will also increase as it becomes increasingly difficult to find the right technicians to repair legacy equipment. When it comes to data center cooling, innovative cooling systems use less floor space and are often much simpler to access and maintain, which also reduces maintenance time.
Limitations to Data Center Flexibility
In today's data centers, the term flexibility means deploying data center assets in innovative ways to enable data center businesses to grow faster. As the market changes rapidly, data center operators also need to react quickly. Traditional, outdated physical infrastructure limits this flexibility, and installing advanced IT equipment in existing data center facilities limits the benefits of adopting new technologies. In some cases, new IT technologies overload existing infrastructure and even cause it to fail. If an existing UPS power supply fails to meet an organization's current or future mission-critical performance requirements (e.g., required redundancy and runtime levels to support the entire IT load), the UPS power supply is in an End-of-Life state. Newer technologies, such as modular, scalable infrastructure, mobile prefabricated infrastructure, are key drivers of data center flexibility as they support rapid business expansion.
Modern data center physical infrastructure systems now provide data operators with warning signs of system aging. For example, instead of detecting problems when UPS power systems fail, new remote monitoring services provide data on the life and warranty of components such as AC capacitors, batteries, DC capacitors, fans, power supplies, contactors, circuit breakers, power modules, air filters, and more.
Thank you for your reading. The above is the content of "What problems will arise from ignoring the modernization of data center physical infrastructure". After studying this article, I believe that you have a deeper understanding of what problems will arise from ignoring the modernization of data center physical infrastructure. The specific use situation still needs to be verified by practice. Here is, Xiaobian will push more articles related to knowledge points for everyone, welcome to pay attention!
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.