Hello everyone, Lin Fei to answer the above questions, air conditioning maintenance code replication, air conditioning maintenance code many people do not know, now let's take a look!
Guangdong Zhigao Air conditioning Co., Ltd., founded in 1993, is headquartered in Nanhai District, Foshan City, an industrial town in the Pearl River Delta. Is a large modern enterprise group mainly engaged in the production and sales of domestic and commercial air conditioners. Therefore, today, Bian Xiao shares with you the fault code of Zhigao air conditioner, hoping to help friends in need.
Part one: some fault codes of household Zhigao air conditioners.
First, Chi Ko 285, 325, 388, 418 wall-mounted air conditioning fault code table:
Including: 03pr. 04pr. 05pr. 06pr. 07pr. 08pr. 09pr. 10pr. 11pr. 12pr.
Fault content running lamp LED1
Driving light timing light
The failure of the indoor coil temperature sensor flashes every 8 seconds.
The room temperature sensor fault flashes twice / lights up for 8 seconds.
The abnormal fault light of the outdoor unit is lit for 5 times / 8 seconds.
The indoor fan failure flashes 6 times / 8 seconds.
Once it is on, it turns on for 0.5 seconds and goes out for 0.5 seconds.
Only detected in standby state, showing indoor coil sensor failure and indoor temperature sensor failure.
If the indoor fan runs for 30 seconds without feedback signal, turn off the air conditioner and show the indoor fan failure.
two. Shigao crystal color series wall-mounted air conditioner fault code:
Including: 02, 16, 18, 19, 20.
Fault content digital tube display code description
Displays the on / off status of the room temperature sensor fault L2. If a failure occurs at the same time, the code L1 will be displayed and the room temperature will be displayed immediately after repair.
Failure of indoor coil temperature sensor
L1 indoor fan failure
When the L6 indoor fan is running, if there is no feedback signal within 30 seconds, turn off and display the L6.
Abnormal failure of outdoor unit
After E5 turns off the display "E5", the setting temperature is valid, but the digital tube does not display. You can restart the computer with the "emergency" or remote control "on / off" button, and the digital tube will show the room temperature.
Three. "Tian" series and well-off series hang up (51 and below 51) model fault code
Including: 25, 26, 42, 43, 45, 46, 47, 48, 50, 51, 52.
Fault content digital tube display status
Indoor coil sensor fault E3
2 fault code of Zhigao air conditioner
Indoor temperature sensor fault E2
Abnormal E4 outdoor unit
Indoor fan fault E5
Frost DF
four. Zhigao 18NV/24NV air conditioner (5100-6600W):
Including: 17, 34, 36, 37.
Therefore, the accessible traffic light LED1 states
The sensor flashes twice / 4 seconds at room temperature and displays when off.
The sensor flashes 3 times / 5 seconds and displays when off.
The outdoor unit flashes abnormally 4 times / 6 seconds, which is displayed when it is turned on or off.
No fan feedback (PG only) flashes 5 times / 7 seconds and displays when the machine is turned off.
No AC zero detection signal (PG only) flashes 6 times / 8 seconds and displays when the machine is turned off.
In a flash, it turns on for 0.5 seconds and turns off for 0.5 seconds. For example, 2 flashes / 4 seconds: 0.5 seconds on, 0.5 seconds off, 0.5 seconds on, 0.5 seconds off.
Stop for 2 seconds, a cycle lasts 4 seconds, and so on. For non-inverters, the following explanation for lamp flicker will not be repeated.
Note: no fan feedback, no AC zero detection signal, all indoor fan failures.
Fifth, the self-check code table of the whole operating board of LED display cabinet:
Including: 05, 06, 07, 08.
Self-test information self-test code description
Outdoor unit abnormal 12-29 1-18 outdoor unit failure
Room temperature sensor fault 11-28 1-18 thermistor fault
Indoor coil sensor fault 10-27 1-18 thermistor fault
External feedback fault 8-25-1-18 overcurrent and grid anomalies
3. Fault code of Zhigao air conditioner
Overheating and frosting protects 7-24 1-18 wind short-circuit circulation, internal fan failure and air filter clogging.
Note: (1-18) the light is always on, which is used to display the cabinet self-test code, and other lights are used to indicate the self-test information.
Intransitive verb Zhi Gao 2HP gorgeous cabinet air conditioning and gorgeous VFD cabinet machine fault code table:
Including: 02, 04, 09, 10.
Fault content digital tube display code description
Room temperature Fault 11 LCD displays "fault" and fault code at room temperature.
Tube temperature sensor fault 10
Overheat protection of heating inner coil 7
Anti-freezing protection of internal refrigeration coil 7
Outdoor unit abnormal 12
Abnormal or overcurrent protection 13
7. Failure code of digital tube machine cabinet machine (111.17pd18) 20pc22)
Multi-color screen display code of self-test with double 8 digital tube in the middle
Indoor pipe temperature sensor fault E3
Room temperature sensor fault E2
Frost protection E8
Overheat protection E8
Overcurrent or phase sequence protection E7
8. List of frequency conversion on-hook and cabinet failure display
An on-hook fault display table
Internal / external machine fault indication fault content
1. Indoor fault
1. Fault code of Zhigao air conditioner
The timing light is always on / the running light is flashing.
1 / 8 second indoor coil sensor abnormal
2 / 8 seconds indoor ambient temperature sensor abnormal
6 times / 8 seconds fan motor abnormal
2. Outdoor anomalies
Running light flashing continuously / sleeping light flashing
1 / 8 second outdoor ambient temperature sensor abnormal
2 / 8 seconds outdoor coil sensor abnormality
4 times / 8 s exhaust temperature sensor abnormal
Running light is always on / sleep light is flashing
7 times / 8 seconds module protection
Overcurrent protection of 3 times / 8 s press
5 times / 8 seconds lack of refrigerant, press overheat protection
6 communication failures / 8 seconds
Second cabinet machine
Fault content (yellow light) number of times the fault indicator flashes
Module fault flash 1 time
Communication failure flashed twice
Keep flashing 3 times
Lack of fluorine protection or four-way valve fault flash 4 times
The compressor flashed 5 times.
Compressor exhaust temperature is too high to flash for 6 times
External motherboard temperature sensor failure or excessive temperature (> 65 ℃) flash 7 times
Compressor exhaust temperature sensor fault flashes 8 times
Outdoor coil midpoint sensor fault flashes 9 times
5. Fault code of Zhigao air conditioner
Outdoor environment sensor fault flashes 11 times
Outdoor motherboard software reset and flash 12 times
The fault indicator flashes at a frequency of 1Hz (that is, an interval of 1 second), and each fault flashes for at least 30 seconds.
LCD fault is Fn,n corresponding to the flicker times of the above table, such as F2 indicates communication failure.
Three frequency converters, one dragging and one cabinet machine (indicator lamp shows model) fault code
2004-8-10
Fault display fault content
12-29 light on communication failure
11-28 lamp on room temperature sensor fault
10-27 lamp on indoor coil temperature sensor fault
9-26 Lamp Indoor Coil temperature overheating Protection
8-25 lamp on fluorine deficiency protection
7-24 light module protection
6-23 light system overcurrent protection or no-load overcurrent fault
Exhaust overheating failure of 5-22 Lamp Compressor
4-21 light on outdoor watchdog reset failure
3-20 light on outdoor sensor fault
1-18 lights on protection state
IV. KFR-51LW/BP
1) display failure of indoor unit
No LCD barrier capacity
1F1 communication failure
2F3 abnormal temperature sensor in indoor room
3F6 Indoor Coil temperature Sensor abnormal
4 failure of communication power supply without display
2) display failure of outdoor unit
No LCD barrier capacity
6. Fault code of Zhigao air conditioner
1 E1 IPM module failure
2the current of E2 compressor is too high
3E3 compressor temperature is too high
4E4 Outdoor temperature Sensor abnormal
5 failure of communication power supply without display
Part II: fault codes of commercial Shigao air conditioners
one。 Fault code table of four-lamp smallpox air conditioner
Self-test information light-emitting tube self-test code description
Defrosting prompt blinks 1 time / 1 second power on display (running light)
Anti-cold wind prompt blinks 1 time / 3 seconds power on display (running light)
Room temperature sensor fault running light flashes 2 times / 4 seconds off display, the protection light is always on
Tube temperature sensor fault running light flashes 3 times / 5 seconds off display, the protection light is always on
The outdoor unit abnormal running light flashes 4 times / 6 seconds off display, and the protection light is always on.
Indoor evaporator frosting protection running light flashes 5 times / 7 seconds off display, the protection light is always on
External feedback fault running light flashes 7 times / 9 seconds off display, the protection light is always on
Overheat protection running light flashes 8 times / 10 seconds off display, the protection light is always on
Water pump fault running light flashes 9 times / 11 seconds off display, the protection light is always on
Fault code list of two-lamp ceiling machine
Fault significance of flashing red light
7. Fault code of Zhigao air conditioner
2 times / 4 second coil failure
3 times / 5 seconds room temperature failure
4 times / 6 seconds pump failure
5 outdoor failures / 7 seconds
6 times / 8 seconds anti-frosting protection
7 / 9 second outdoor unit (overcurrent, abnormal grid voltage)
8 times / 10 seconds overheat protection
Third, air duct machine, fan coil unit, clean air conditioner LCD display fault code table
Fault content LCD display content
Indoor room temperature sensor fault E2
Indoor coil temperature sensor fault E3
Low voltage protection E4
Frost protection E8
Overcurrent or phase sequence protection E7
Overheat protection E8
System control motherboard communication fault E1
Outdoor unit abnormal protection E9
Price list of air conditioners in Shigao
Zhigao KFR-32GW/MD (M96A) + 1:
Price: 1699 yuan
Zhigao KFR-36GW/ABP119+3A:
Price: 2599 yuan
Zhigao KFR-51GW/D96+N2:
Price: 2999 yuan
Once the air conditioner breaks down, you should check the air conditioner fault code as soon as possible. Only in this way can we quickly find out what the problem is. I hope the fault code of Zhigao air conditioner introduced above can help you.
At the end of this article, I hope it will be helpful to you.
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.