Operation instructions for replacing motherboard for SUN T4-1 equipment
Scope of application: SUN T4\ T5 series equipment
Applicable environment: SUN T4 equipment motherboard failure requires replacement of motherboard
Scope of failure: modify the default boot device path
Preparatory work
1.1 tool preparation: serial line, console line, screwdriver
1.2Software preparation: CRT or other remote management login software, Oracle System Handbook
two。 Collect faulty equipment information
2.1 the device can start the system normally and collect the following information in the system:
Prtdiag-v view motherboard and parts status # dmesg view system startup information # eeprom view eeprom setting information eeprom
Ttya-rts-dtr-off=false
Ttya-ignore-cd=true
Keyboard-layout=US-English
Reboot-command: data not available.
Security-mode=none
Security-password: data not available.
Security-#badlogins=0
Verbosity=min
Diag-switch?=false
Local-mac-address?=true
Fcode-debug?=false
Scsi-initiator-id=7
Oem-logo: data not available.
Oem-logo?=false
Oem-banner: data not available.
Oem-banner?=false
Ansi-terminal?=true
Screen-#columns=80
Screen-#rows=34
Ttya-mode=9600,8,n,1,-
Output-device=virtual-console
Input-device=virtual-console
Auto-boot-on-error?=false
Load-base=16384
Auto-boot?=true
Os-root-device: data not available.
Network-boot-arguments: data not available.
Boot-command=boot
Boot-file: data not available.
Boot-device=? Bootdisk system default boot device name
Multipath-boot?=false
Boot-device-index=0
Use-nvramrc?=true
Nvramrc=devalias bootdisk / pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w3ebc7c41c045e4dd,0:a
Device name absolute path of the device to which the bootdisk device name is linked
. "ChassisSerialNumber 1146BDYD25" cr
Format to view hard disk status information format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
C2t3EBC7C41C045E4DDd0 / pci@400/pci@1/pci@0/pci@4/scsi@0/iport@v0/disk@w3ebc7c41c045e4dd,0br/ > / pci@400/pci@1/pci@0/pci@4/scsi@0/iport@v0/disk@w3ebc7c41c045e4dd,0
2.1 the device does not boot properly. The device collects the following information in OK mode:
{0} ok probe-scai-allprobe-scsi-all
/ pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2br/ > probe-scsi-all
/ pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2
/ pci@400/pci@2/pci@0/pci@4/scsi@0
FCode Version 1.00.64, MPT Version 2.00, Firmware Version 9.05.00.00
Target 9
Unit 0 Removable Read Only device TEAC DV-W28SS-W 1.0A
SATA device PhyNum 6
/ pci@400/pci@1/pci@0/pci@4/scsi@0 hard disk backplane path
FCode Version 1.00.64, MPT Version 2.00, Firmware Version 9.05.00.00
Target 381 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 3ebc7c41c045e4dd VolumeWWID 0ebc7c41c045e4dd
{0} ok select / pci@400/pci@1/pci@0/pci@4/scsi@0
{0} ok select / pci@400/pci@2/pci@0/pci@4/scsi@0
{0} ok show-volumes
Show-volumes
Volume 0 Target 381Type RAID1 (Mirroring)
WWID 0ebc7c41c045e4dd
Optimal Enabled Inactive
2 Members 583983104 Blocks, 298 GB
Disk 1
Primary Optimal
Target 9 HITACHI H109030SESUN300G A31A PhyNum 0
Disk 0
Secondary Optimal
Target a HITACHI H109030SESUN300G A31A PhyNum 1
{0} ok unselect-dev
{0} ok printenv
Printenv
Variable Name Value Default Value
Ttya-rts-dtr-off false false
Ttya-ignore-cd true true
Keyboard-layout US-English
Reboot-command
Security-mode none No default
Security-password No default
Security-#badlogins 0 No default
Verbosity min min
Diag-switch? False false
Local-mac-address? True true
Fcode-debug? False false
Scsi-initiator-id 7 7
Oem-logo No default
Oem-logo? False false
Oem-banner No default
Oem-banner? False false
Ansi-terminal? True true
Screen-#columns 80 80
Screen-#rows 34 34
Ttya-mode 9600, eight, one, six, eight, six, eight, one, one, six, six, four, four, six, four, six, six,
Output-device virtual-console virtual-console
Input-device virtual-console virtual-console
Auto-boot-on-error? False false
Load-base 16384 16384
Auto-boot? False true
Os-root-device
Network-boot-arguments
Boot-command boot boot
Boot-file
Boot-device / pci@400/pci@1/pci@0/pci... Disk net
Multipath-boot? False false
Boot-device-index 0 0
Use-nvramrc? False false
Nvramrc. "ChassisSerialNumber 1...
Error-reset-recovery boot boot
-> show faulty
Target | Property | Value
-+
3 after collecting information, shut down the operating system, turn off the power, and follow the handbook replacement steps to replace the motherboard.
3.1 before the equipment will be replaced, the motherboard will take photos to record the memory location and cable connection.
3.2 remove the faulty motherboard memory stick and install it in the new motherboard memory slot in its original location.
3.3.Unscrew the two screws on the rear PCI bezel of the machine, remove the upper baffle of the PCI card, and remove the PCI card
3.4 unscrew the 5 screws at the top of the motherboard and unplug the connecting cable between the machine and the motherboard.
3.5 remove the faulty motherboard, install a new motherboard into the device, and check the cable connection and memory location
4. Set the device self-startup path
4.1 Power up the equipment and record the boot log.
-> start / SYS
-> start / SP/console
4.2 if the new motherboard is replaced, the original SP (ILOM card) may not match the motherboard firmware version. The message is as follows: you need to upgrade the firmware version or replace the faulty motherboard SP card.
Warning: Product identification data missing. System may not function properly.
Service must update product identification data. Contact Service immediately.
Unrecognized Chassis: This module is installed in an unknown or unsupported
Chassis. You must upgrade the firmware to a newer version that supports
This chassis.
Hostname: ORACLESP-AK00129974
4.3 activate volumes information
{0} ok select / pci@400/pci@1/pci@0/pci@4/scsi@0
{0} ok select / pci@400/pci@2/pci@0/pci@4/scsi@0
{0} ok show-volumes
{0} ok show-volumes
Volume 0 Target 381Type RAID1 (Mirroring)
WWID 0ebc7c41c045e4dd
Optimal Enabled Inactive
2 Members 583983104 Blocks, 298 GB
Disk 1
Primary Optimal
Target 9 HITACHI H109030SESUN300G A31A PhyNum 0
Disk 0
Secondary Optimal
Target a HITACHI H109030SESUN300G A31A PhyNum 1
{0} ok probe-scsi-all/pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2br/ > / pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2
/ pci@400/pci@2/pci@0/pci@4/scsi@0
FCode Version 1.00.64, MPT Version 2.00, Firmware Version 9.05.00.00
Target 9
Unit 0 Removable Read Only device TEAC DV-W28SS-W 1.0A
SATA device PhyNum 6
/ pci@400/pci@1/pci@0/pci@4/scsi@0
FCode Version 1.00.64, MPT Version 2.00, Firmware Version 9.05.00.00
Target 381 Volume 0
Unit 0 Disk LSI Logical Volume 3000 583983104 Blocks, 298 GB
VolumeDeviceName 3ebc7c41c045e4dd VolumeWWID 0ebc7c41c045e4dd
{0} ok 0 activate-volume 0 corresponding to the Volume number activate-volume activation command
Volume 0 is now activated
{0} ok unselect-dev
Nvalias bootdisk / pci@400/pci@1/pci@0/pci@4/scsi@0/disk@w3ebc7c41c045e4dd,0:a
Set the alias to bootdisk for the boot device path
{0} ok nvalias set aliases command bootdisk alias name / pci@400/pci@1/pci@0/pci@4/scsi@0 hard disk backplane path
Disk@w3ebc7c41c045e4dd hard disk path (volume path) VolumeDeviceName is preceded by w
0 hard disk number Unit 0
A the first partition of the hard disk
Setenv boot-device? Bootdisk sets the auto-startup device to bootdisk
{0} ok setenv auto-boot? True device starts automatically when it starts up
{0} ok boot starts the system
After starting the system normally, be sure to modify the system time
Welcome to subscribe "Shulou Technology Information " to get latest news, interesting things and hot topics in the IT industry, and controls the hottest and latest Internet news, technology news and IT industry trends.
Views: 0
*The comments in the above article only represent the author's personal views and do not represent the views and positions of this website. If you have more insights, please feel free to contribute and share.
Continue with the installation of the previous hadoop.First, install zookooper1. Decompress zookoope
"Every 5-10 years, there's a rare product, a really special, very unusual product that's the most un
© 2024 shulou.com SLNews company. All rights reserved.